| Weight: |
192 kg
|
| Equipment: |
Built-in boiler, display
|
| Description: |
Type of heating boiler: gas, max. heating power: 29.70 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
|
| Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
|
| Additional Information: |
Productivity of hot water for the first 30 minutes at Δt
|
| Control: |
Electronic
|
| Dimensions WxHxD: |
650x850x600mm
|
| Installation: |
Floor
|
| Efficiency: |
90 %
|
| Fuel: |
Natural gas, liquefied gas
|
| Mains voltage: |
Single-phase
|
| Chimney diameter: |
140 mm
|
| Thermal power: |
14.90 - 29.70 kW
|
| LPG consumption: |
2.56 kg/h
|
| The volume of the built-in boiler: |
50 l
|
| The combustion chamber: |
Open
|
| Max. water pressure in the DHW circuit: |
8 bar
|
| Max. water pressure in the heating circuit: |
3 bar
|
| Temperature in the DHW circuit: |
5 - 65 °С
|
| Heat carrier temperature: |
30 - 85 °С
|
| Thermal load: |
17 - 33 kW
|
| Expansion tank volume: |
10 l
|
| Burner: |
Gas
|
| Gas connection: |
1/2"
|
| Branch pipe for connecting the DHW circuit: |
1/2"
|
| Heating circuit connection: |
3/4"
|
| Permissible LPG pressure: |
30 mbar
|
| Nominal pressure of natural gas: |
20 mbar
|
| Natural gas consumption: |
3.49 cu. m/hour
|
| Number of circuits: |
Double-circuit
|
| Primary heat exchanger material: |
Cast iron
|
| Type of heating boiler: |
Gas, convection
|
| Hot water capacity at t 25°C: |
17 l/min
|
| Hot water capacity at t 35°C: |
12.1 l/min
|