| Weight: |
38.8 kg
|
| Equipment: |
Display
|
| Description: |
Type of heating boiler: gas, max. thermal power: 27 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
|
| Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
|
| Additional Information: |
Admissible pressure of liquefied gas butane 30 mbar
|
| Control: |
Electronic
|
| Dimensions WxHxD: |
400x825x370 mm
|
| Installation: |
Wall-mounted
|
| Fuel: |
Natural gas, liquefied gas
|
| Mains voltage: |
Single-phase
|
| Chimney diameter: |
130 mm
|
| Thermal power: |
8.30 - 27 kW
|
| LPG consumption: |
2.3 kg/hour
|
| The combustion chamber: |
Open
|
| Max. water pressure in the DHW circuit: |
10 bar
|
| Max. water pressure in the heating circuit: |
3 bar
|
| Max. coolant temperature: |
85 °С
|
| Temperature in the DHW circuit: |
40 - 65 °С
|
| Thermal load: |
9.40 - 30 kW
|
| Expansion tank volume: |
8 l
|
| Burner: |
Gas
|
| Gas connection: |
3/4"
|
| Branch pipe for connecting the DHW circuit: |
1/2"
|
| Heating circuit connection: |
3/4"
|
| Permissible LPG pressure: |
37 mbar
|
| Nominal pressure of natural gas: |
7 - 30 mbar
|
| Natural gas consumption: |
3.1 cu. m/hour
|
| Number of circuits: |
Double-circuit
|
| Type of heating boiler: |
Gas, convection
|
| Hot water capacity at t 20°C: |
17.1 l/min
|
| Hot water capacity at t 30°C: |
11.4 l/min
|
| Hot water capacity at t 50°C: |
6.8 l/min
|