| Weight: |
39.8 kg
|
| Equipment: |
Display
|
| Description: |
Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
|
| Peculiarities: |
Pressure gauge, external control connector, thermometer
|
| Control: |
Electronic
|
| Dimensions WxHxD: |
400x783x365 mm
|
| Installation: |
Wall-mounted
|
| Efficiency: |
92.8 %
|
| Fuel: |
Natural gas, liquefied gas
|
| Mains voltage: |
Single-phase
|
| Thermal power: |
9.90 - 23.70 kW
|
| Heated area: |
220 sq.m
|
| LPG consumption: |
1.98 kg/hour
|
| The combustion chamber: |
Closed
|
| Max. water pressure in the DHW circuit: |
10 bar
|
| Burner: |
Gas
|
| Nominal pressure of natural gas: |
3.50 mbar
|
| Natural gas consumption: |
2.7 cu. m/hour
|
| Number of circuits: |
Double-circuit
|
| Primary heat exchanger material: |
Copper
|
| Type of heating boiler: |
Gas, convection
|
| Hot water capacity at t 25°C: |
14.9 l/min
|
| Hot water capacity at t 30°C: |
12.4 l/min
|