Change history for item: Double conversion UPS SNR Element 1000VA-36VDC without battery, charge current 6A

  1. Donny Darko 24 August 2023 13:16:31
    1. Create: Width #432436
      Value: 440
    2. Create: Height #432437
      Value: 87
    3. Create: Description #16589641
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16589642
      Value: SNR
    5. Create: Output power apparent #16589643
      Value: 1000 VA
    6. Create: Output power active #16589644
      Value: 900 W
    7. Create: Output waveform #16589645
      Value: Sinusoid
    8. Create: Input voltage #16589646
      Value: 1-phase
    9. Create: Output voltage #16589647
      Value: 1-phase
    10. Create: Number of output power connectors total #16589648
      Value: 6
    11. Create: Number of UPS outlets #16589649
      Value: 6
    12. Create: Type of output power connectors #16589650
      Value: IEC 320 C13 computer
    13. Create: Efficiency #16589651
      Value: 87 %
    14. Create: Min. input voltage #16589652
      Value: 160 V
    15. Create: Max. input voltage #16589653
      Value: 290 V
    16. Create: Min. input frequency #16589654
      Value: 46 Hz
    17. Create: Max. input frequency #16589655
      Value: 64 Hz
    18. Create: Output voltage stability Battery mode #16589656
      Value: 2 %
    19. Create: Min. output frequency #16589657
      Value: 49 Hz
    20. Create: Max. output frequency #16589658
      Value: 61 Hz
    21. Create: Fuse type #16589659
      Value: Auto
    22. Create: Protection functions #16589660
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    23. Create: Interfaces #16589661
      Value: RS-232, USB, slot
    24. Create: Information display #16589662
      Value: LCD screen
    25. Create: Peculiarities #16589663
      Value: Rackmountable, audible alarm, SNMP support, additional battery connection, noise filtering, cold start
    26. Create: Depth #16589664
      Value: 430 mm
    27. Create: Weight #16589665
      Value: 115 kg
    28. Create: Image #13092823
      URL: https://avatars.mds.yandex.net/get-mpic/4599566/img_id2973332898491543849.jpeg/orig
    29. Create: Image #13092824
      URL: https://avatars.mds.yandex.net/get-mpic/4409630/img_id7271265310122177153.jpeg/orig
    30. Create: Image #13092825
      URL: https://avatars.mds.yandex.net/get-mpic/1614201/img_id2402476279525045853.jpeg/orig
    31. Create: Image #13092826
      URL: https://avatars.mds.yandex.net/get-mpic/1545401/img_id6496251096805764408.jpeg/orig
    32. Create: Preview image #13092827
      URL: https://avatars.mds.yandex.net/get-mpic/4599566/img_id2973332898491543849.jpeg/orig
  2. Donny Darko 23 April 2023 18:28:09
    Name: Double conversion UPS SNR Element 1000VA-36VDC without battery, charge current 6A; Catalog: Uninterruptible power supplies