Change history for item: Double conversion UPS SNR Element 2000VA-48VDC without battery, charge current 12A

  1. Donny Darko 24 August 2023 13:16:19
    1. Create: Width #432426
      Value: 440
    2. Create: Height #432427
      Value: 87
    3. Create: Description #16589295
      Value: Output power apparent: 2000 VA, output power active: 1800 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 6, number of output power connectors total: 6, height
    4. Create: Brand #16589296
      Value: SNR
    5. Create: Output power apparent #16589297
      Value: 2000 VA
    6. Create: Output power active #16589298
      Value: 1800 W
    7. Create: Operating time at half load #16589299
      Value: 11 min
    8. Create: Output waveform #16589300
      Value: Sinusoid
    9. Create: Input voltage #16589301
      Value: 1-phase
    10. Create: Output voltage #16589302
      Value: 1-phase
    11. Create: Number of output power connectors total #16589303
      Value: 6
    12. Create: Number of UPS outlets #16589304
      Value: 6
    13. Create: Type of output power connectors #16589305
      Value: IEC 320 C13 computer
    14. Create: Efficiency #16589306
      Value: 87 %
    15. Create: THD #16589307
      Value: 5 %
    16. Create: Min. input voltage #16589308
      Value: 160 V
    17. Create: Max. input voltage #16589309
      Value: 290 V
    18. Create: Min. input frequency #16589310
      Value: 46 Hz
    19. Create: Max. input frequency #16589311
      Value: 64 Hz
    20. Create: Output voltage stability Battery mode #16589312
      Value: 2 %
    21. Create: Crest factor #16589313
      Value: 3
    22. Create: Fuse type #16589314
      Value: Auto
    23. Create: Protection functions #16589315
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    24. Create: Interfaces #16589316
      Value: RS-232, USB, slot
    25. Create: Charging time #16589317
      Value: 8 h
    26. Create: Information display #16589318
      Value: LCD screen
    27. Create: Peculiarities #16589319
      Value: Rackmountable, audible alarm, SNMP support, additional battery connection, noise filtering, cold start
    28. Create: Noise level #16589320
      Value: 55 dB
    29. Create: Depth #16589321
      Value: 552 mm
    30. Create: Weight #16589322
      Value: 17.5 kg
    31. Create: Height in units #16589323
      Value: 2 U
    32. Create: Additional Information #16589324
      Value: EPO connector
    33. Create: Image #13092783
      URL: https://avatars.mds.yandex.net/get-mpic/1865723/img_id4761472026437708562.jpeg/orig
    34. Create: Image #13092784
      URL: https://avatars.mds.yandex.net/get-mpic/4322217/img_id25920805165570070.jpeg/orig
    35. Create: Image #13092785
      URL: https://avatars.mds.yandex.net/get-mpic/3986581/img_id5827203506447699760.jpeg/orig
    36. Create: Image #13092786
      URL: https://avatars.mds.yandex.net/get-mpic/1674591/img_id400576917159290956.jpeg/orig
    37. Create: Preview image #13092787
      URL: https://avatars.mds.yandex.net/get-mpic/1865723/img_id4761472026437708562.jpeg/orig
  2. Donny Darko 23 April 2023 18:28:07
    Name: Double conversion UPS SNR Element 2000VA-48VDC without battery, charge current 12A; Catalog: Uninterruptible power supplies