Change history for item: Double conversion UPS SNR Element 1000VA-24VDC

  1. Donny Darko 24 August 2023 13:15:36
    1. Create: Width #432390
      Value: 440
    2. Create: Height #432391
      Value: 87
    3. Create: Description #16588171
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16588172
      Value: SNR
    5. Create: Output power apparent #16588173
      Value: 1000 VA
    6. Create: Output power active #16588174
      Value: 900 W
    7. Create: Output waveform #16588175
      Value: Sinusoid
    8. Create: Input voltage #16588176
      Value: 1-phase
    9. Create: Output voltage #16588177
      Value: 1-phase
    10. Create: Number of output power connectors total #16588178
      Value: 6
    11. Create: Number of UPS outlets #16588179
      Value: 6
    12. Create: Type of output power connectors #16588180
      Value: IEC 320 C13 computer
    13. Create: Efficiency #16588181
      Value: 94 %
    14. Create: THD #16588182
      Value: 3 %
    15. Create: Min. input voltage #16588183
      Value: 160 V
    16. Create: Max. input voltage #16588184
      Value: 290 V
    17. Create: Min. input frequency #16588185
      Value: 46 Hz
    18. Create: Max. input frequency #16588186
      Value: 64 Hz
    19. Create: Input power factor #16588187
      Value: 0.98
    20. Create: Output voltage stability Battery mode #16588188
      Value: 2 %
    21. Create: Min. output frequency #16588189
      Value: 49 Hz
    22. Create: Max. output frequency #16588190
      Value: 61 Hz
    23. Create: Crest factor #16588191
      Value: 3
    24. Create: Fuse type #16588192
      Value: Auto
    25. Create: Protection functions #16588193
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    26. Create: Interfaces #16588194
      Value: RS-232, USB, slot
    27. Create: Charging time #16588195
      Value: 8 h
    28. Create: Information display #16588196
      Value: LCD screen
    29. Create: Peculiarities #16588197
      Value: Auto By-pass, Battery swappable, Rackmountable, Hot swappable batteries, Audible alarm, Additional battery connection, Noise filtering, Cold start
    30. Create: Noise level #16588198
      Value: 55 dB
    31. Create: Depth #16588199
      Value: 430 mm
    32. Create: Weight #16588200
      Value: 15.7 kg
    33. Create: Height in units #16588201
      Value: 2 U
    34. Create: Image #13092671
      URL: https://avatars.mds.yandex.net/get-mpic/4599566/img_id1203403343804553805.jpeg/orig
    35. Create: Image #13092672
      URL: https://avatars.mds.yandex.net/get-mpic/4055688/img_id2059905547165699704.jpeg/orig
    36. Create: Image #13092673
      URL: https://avatars.mds.yandex.net/get-mpic/4362548/img_id5945968368557091383.jpeg/orig
    37. Create: Image #13092674
      URL: https://avatars.mds.yandex.net/get-mpic/3927509/img_id8060100388458331545.jpeg/orig
    38. Create: Image #13092675
      URL: https://avatars.mds.yandex.net/get-mpic/1925870/img_id2226938287949597933.jpeg/orig
    39. Create: Preview image #13092676
      URL: https://avatars.mds.yandex.net/get-mpic/4599566/img_id1203403343804553805.jpeg/orig
  2. Donny Darko 23 April 2023 18:28:02
    Name: Double conversion UPS SNR Element 1000VA-24VDC; Catalog: Uninterruptible power supplies