Change history for item: Double conversion UPS Helior Sigma RM1 KL

  1. Donny Darko 24 August 2023 13:12:23
    1. Create: Width #432302
      Value: 440
    2. Create: Height #432303
      Value: 44
    3. Create: Description #16585067
      Value: Output power apparent: 1000 VA, output power active: 800 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 2, total number of power output connectors: 2, time
    4. Create: Brand #16585068
      Value: Helior
    5. Create: Output power apparent #16585069
      Value: 1000 VA
    6. Create: Output power active #16585070
      Value: 800 W
    7. Create: Operating time at full load #16585071
      Value: 5 minutes
    8. Create: Output waveform #16585072
      Value: Sinusoid
    9. Create: Input voltage #16585073
      Value: 1-phase
    10. Create: Output voltage #16585074
      Value: 1-phase
    11. Create: Number of output power connectors total #16585075
      Value: 2
    12. Create: Number of UPS outlets #16585076
      Value: 2
    13. Create: Type of output power connectors #16585077
      Value: IEC 320 C13 computer
    14. Create: Min. input voltage #16585078
      Value: 138 V
    15. Create: Max. input voltage #16585079
      Value: 300 V
    16. Create: Min. input frequency #16585080
      Value: 45 Hz
    17. Create: Max. input frequency #16585081
      Value: 65 Hz
    18. Create: Input power factor #16585082
      Value: 0.98
    19. Create: Output voltage stability Battery mode #16585083
      Value: 1 %
    20. Create: Crest factor #16585084
      Value: 3
    21. Create: Protection functions #16585085
      Value: Short circuit protection, high voltage surge protection, overload protection
    22. Create: Interfaces #16585086
      Value: RS-232
    23. Create: Information display #16585087
      Value: LCD screen
    24. Create: Peculiarities #16585088
      Value: Automatic By-pass, Battery swappable, Rack-mountable, Audible alarm, Additional battery connection, Manual By-pass, Cold start
    25. Create: Noise level #16585089
      Value: 50 dB
    26. Create: Depth #16585090
      Value: 454 mm
    27. Create: Weight #16585091
      Value: 12 kg
    28. Create: Height in units #16585092
      Value: 1 U
    29. Create: Additional Information #16585093
      Value: Battery set voltage 24V 2x12V
    30. Create: Image #13092363
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id6097147134031210669/orig
    31. Create: Preview image #13092364
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id6097147134031210669/orig
  2. Donny Darko 23 April 2023 18:27:42
    Name: Double conversion UPS Helior Sigma RM1 KL; Catalog: Uninterruptible power supplies