Change history for item: Double conversion UPS Helior Sigma 4 KL

  1. Donny Darko 24 August 2023 13:12:14
    1. Create: Width #432300
      Value: 88
    2. Create: Height #432301
      Value: 440
    3. Create: Description #16584914
      Value: Output power apparent: 4000 VA, output power active: 2800 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 4, total number of power output connectors: 4, time
    4. Create: Brand #16584915
      Value: Helior
    5. Create: Output power apparent #16584916
      Value: 4000 VA
    6. Create: Output power active #16584917
      Value: 2800 W
    7. Create: Operating time at full load #16584918
      Value: 5 minutes
    8. Create: Output waveform #16584919
      Value: Sinusoid
    9. Create: Input voltage #16584920
      Value: 1-phase
    10. Create: Output voltage #16584921
      Value: 1-phase
    11. Create: Number of output power connectors total #16584922
      Value: 4
    12. Create: Number of UPS outlets #16584923
      Value: 4
    13. Create: Type of output power connectors #16584924
      Value: IEC 320 C13 computer
    14. Create: Min. input voltage #16584925
      Value: 138 V
    15. Create: Max. input voltage #16584926
      Value: 300 V
    16. Create: Min. input frequency #16584927
      Value: 45 Hz
    17. Create: Max. input frequency #16584928
      Value: 65 Hz
    18. Create: Input power factor #16584929
      Value: 0.98
    19. Create: Output voltage stability Battery mode #16584930
      Value: 1 %
    20. Create: Crest factor #16584931
      Value: 3
    21. Create: Protection functions #16584932
      Value: Short circuit protection, high voltage surge protection, overload protection
    22. Create: Interfaces #16584933
      Value: RS-232
    23. Create: Information display #16584934
      Value: LCD screen
    24. Create: Peculiarities #16584935
      Value: Automatic By-pass, Battery swappable, Rack-mountable, Audible alarm, Additional battery connection, Manual By-pass, Cold start
    25. Create: Noise level #16584936
      Value: 50 dB
    26. Create: Depth #16584937
      Value: 454 mm
    27. Create: Weight #16584938
      Value: 4.5 kg
    28. Create: Height in units #16584939
      Value: 2 U
    29. Create: Additional Information #16584940
      Value: Battery set voltage 120V 10x12V
    30. Create: Image #13092347
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1738762873428334551/orig
    31. Create: Image #13092348
      URL: https://avatars.mds.yandex.net/get-mpic/397397/img_id1944087559156219758/orig
    32. Create: Preview image #13092349
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1738762873428334551/orig
  2. Donny Darko 23 April 2023 18:27:42
    Name: Double conversion UPS Helior Sigma 4 KL; Catalog: Uninterruptible power supplies