Change history for item: Double conversion UPS Helior Sigma RM6 KSL

  1. Donny Darko 24 August 2023 13:12:04
    1. Create: Width #432292
      Value: 440
    2. Create: Height #432293
      Value: 132
    3. Create: Description #16584666
      Value: Output power apparent: 6000 VA, output power active: 4200 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 4, number of output power connectors total: 4, height
    4. Create: Brand #16584667
      Value: Helior
    5. Create: Output power apparent #16584668
      Value: 6000 VA
    6. Create: Output power active #16584669
      Value: 4200 W
    7. Create: Output waveform #16584670
      Value: Sinusoid
    8. Create: Input voltage #16584671
      Value: 1-phase
    9. Create: Output voltage #16584672
      Value: 1-phase
    10. Create: Number of output power connectors total #16584673
      Value: 4
    11. Create: Number of UPS outlets #16584674
      Value: 4
    12. Create: Type of output power connectors #16584675
      Value: IEC 320 C13 computer
    13. Create: Min. input voltage #16584676
      Value: 138 V
    14. Create: Max. input voltage #16584677
      Value: 300 V
    15. Create: Min. input frequency #16584678
      Value: 45 Hz
    16. Create: Max. input frequency #16584679
      Value: 65 Hz
    17. Create: Input power factor #16584680
      Value: 0.98
    18. Create: Output voltage stability Battery mode #16584681
      Value: 1 %
    19. Create: Crest factor #16584682
      Value: 3
    20. Create: Protection functions #16584683
      Value: Short circuit protection, high voltage surge protection, overload protection
    21. Create: Interfaces #16584684
      Value: RS-232
    22. Create: Information display #16584685
      Value: LCD screen
    23. Create: Peculiarities #16584686
      Value: Automatic By-pass, Battery swappable, Rack-mountable, Audible alarm, Additional battery connection, Manual By-pass, Cold start
    24. Create: Noise level #16584687
      Value: 50 dB
    25. Create: Depth #16584688
      Value: 454 mm
    26. Create: Weight #16584689
      Value: 13.5 kg
    27. Create: Height in units #16584690
      Value: 3 U
    28. Create: Additional Information #16584691
      Value: The operating time of the battery depends on the capacity of the battery pack and the load power.
    29. Create: Image #13092323
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4659783397420153176/orig
    30. Create: Preview image #13092324
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4659783397420153176/orig
  2. Donny Darko 23 April 2023 18:27:41
    Name: Double conversion UPS Helior Sigma RM6 KSL; Catalog: Uninterruptible power supplies