Change history for item: Double conversion UPS GIGALINK GL-UPS-OL01L-1-1/6A

  1. Donny Darko 24 August 2023 13:10:28
    1. Create: Width #432220
      Value: 438
    2. Create: Height #432221
      Value: 88
    3. Create: Description #16582652
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16582653
      Value: GIGALINK
    5. Create: Output power apparent #16582654
      Value: 1000 VA
    6. Create: Output power active #16582655
      Value: 800 W
    7. Create: Output waveform #16582656
      Value: Sinusoid
    8. Create: Input voltage #16582657
      Value: 1-phase
    9. Create: Output voltage #16582658
      Value: 1-phase
    10. Create: Number of output power connectors total #16582659
      Value: 6
    11. Create: Number of UPS outlets #16582660
      Value: 6
    12. Create: Type of output power connectors #16582661
      Value: IEC 320 C13 computer
    13. Create: Efficiency #16582662
      Value: 83 %
    14. Create: THD #16582663
      Value: 3 %
    15. Create: Min. input voltage #16582664
      Value: 160 V
    16. Create: Max. input voltage #16582665
      Value: 275 V
    17. Create: Min. input frequency #16582666
      Value: 40 Hz
    18. Create: Max. input frequency #16582667
      Value: 70 Hz
    19. Create: Input power factor #16582668
      Value: 0.99
    20. Create: Min. output frequency #16582669
      Value: 50 Hz
    21. Create: Max. output frequency #16582670
      Value: 60 Hz
    22. Create: Crest factor #16582671
      Value: 3
    23. Create: Protection functions #16582672
      Value: Short circuit protection, high voltage surge protection, overload protection
    24. Create: Interfaces #16582673
      Value: RS-232, USB, slot
    25. Create: Information display #16582674
      Value: LCD screen
    26. Create: Peculiarities #16582675
      Value: Battery swappable, rack mountable, SNMP support, interference filtering
    27. Create: Noise level #16582676
      Value: 50 dB
    28. Create: Depth #16582677
      Value: 310 mm
    29. Create: Weight #16582678
      Value: 9 kg
    30. Create: Height in units #16582679
      Value: 2 U
    31. Create: Image #13092065
      URL: https://avatars.mds.yandex.net/get-mpic/4080064/img_id164382473413050820.jpeg/orig
    32. Create: Image #13092066
      URL: https://avatars.mds.yandex.net/get-mpic/4362548/img_id3004272831699334907.jpeg/orig
    33. Create: Image #13092067
      URL: https://avatars.mds.yandex.net/get-mpic/4262452/img_id1504004087325365575.jpeg/orig
    34. Create: Image #13092068
      URL: https://avatars.mds.yandex.net/get-mpic/1943683/img_id6673442847023120245.jpeg/orig
    35. Create: Image #13092069
      URL: https://avatars.mds.yandex.net/get-mpic/1707869/img_id3872368794864553855.jpeg/orig
    36. Create: Preview image #13092070
      URL: https://avatars.mds.yandex.net/get-mpic/4080064/img_id164382473413050820.jpeg/orig
  2. Donny Darko 23 April 2023 18:27:28
    Name: Double conversion UPS GIGALINK GL-UPS-OL01L-1-1/6A; Catalog: Uninterruptible power supplies