Change history for item: Double conversion UPS GIGALINK GL-UPS-OL02-1-1

  1. Donny Darko 24 August 2023 13:10:09
    1. Create: Width #432206
      Value: 440
    2. Create: Height #432207
      Value: 88
    3. Create: Description #16582413
      Value: Output power apparent: 2000 VA, output power active: 1800 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 6, number of output power connectors total: 6, inter
    4. Create: Brand #16582414
      Value: GIGALINK
    5. Create: Output power apparent #16582415
      Value: 2000 VA
    6. Create: Output power active #16582416
      Value: 1800 W
    7. Create: Output waveform #16582417
      Value: Sinusoid
    8. Create: Input voltage #16582418
      Value: 1-phase
    9. Create: Output voltage #16582419
      Value: 1-phase
    10. Create: Number of output power connectors total #16582420
      Value: 6
    11. Create: Number of UPS outlets #16582421
      Value: 6
    12. Create: Type of output power connectors #16582422
      Value: IEC 320 C13 computer
    13. Create: Efficiency #16582423
      Value: 91 %
    14. Create: Min. input voltage #16582424
      Value: 160 V
    15. Create: Max. input voltage #16582425
      Value: 290 V
    16. Create: Min. input frequency #16582426
      Value: 45 Hz
    17. Create: Max. input frequency #16582427
      Value: 65 Hz
    18. Create: Input power factor #16582428
      Value: 0.99
    19. Create: Output voltage stability Battery mode #16582429
      Value: 2 %
    20. Create: Crest factor #16582430
      Value: 3
    21. Create: Fuse type #16582431
      Value: Auto
    22. Create: Protection functions #16582432
      Value: Short circuit protection, high voltage surge protection, overload protection
    23. Create: Interfaces #16582433
      Value: RS-232, USB, slot, dry contacts
    24. Create: Charging time #16582434
      Value: 4 h
    25. Create: Information display #16582435
      Value: LCD screen
    26. Create: Peculiarities #16582436
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    27. Create: Noise level #16582437
      Value: 50 dB
    28. Create: Depth #16582438
      Value: 601 mm
    29. Create: Weight #16582439
      Value: 6 kg
    30. Create: Additional Information #16582440
      Value: Without battery; SNMP card or dry contacts sold separately
    31. Create: Image #13092001
      URL: https://avatars.mds.yandex.net/get-mpic/4303914/img_id8902668852640011573.jpeg/orig
    32. Create: Image #13092002
      URL: https://avatars.mds.yandex.net/get-mpic/3927667/img_id7936997211252067502.jpeg/orig
    33. Create: Image #13092003
      URL: https://avatars.mds.yandex.net/get-mpic/4034173/img_id4272315754659851335.jpeg/orig
    34. Create: Preview image #13092004
      URL: https://avatars.mds.yandex.net/get-mpic/4303914/img_id8902668852640011573.jpeg/orig
  2. Donny Darko 23 April 2023 18:27:26
    Name: Double conversion UPS GIGALINK GL-UPS-OL02-1-1; Catalog: Uninterruptible power supplies