Change history for item: Double conversion UPS Tuncmatik Newtech Pro 10kVA LCD Rack-Mount

  1. Donny Darko 24 August 2023 13:04:03
    1. Create: Width #431915
      Value: 438
    2. Create: Height #431916
      Value: 133
    3. Create: Description #16573853
      Value: Total output power: 10000 VA, active output power: 8000 W, Number of output power connectors UPS: 1, number of output power connectors total: 1, height in units: 3 U, interfaces: RS-232, USB, slot
    4. Create: Brand #16573854
      Value: Tuncmatik
    5. Create: Output power apparent #16573855
      Value: 10000 VA
    6. Create: Output power active #16573856
      Value: 8000 W
    7. Create: Output waveform #16573857
      Value: Sinusoid
    8. Create: Input voltage #16573858
      Value: 1-phase
    9. Create: Output voltage #16573859
      Value: 1-phase
    10. Create: Number of output power connectors total #16573860
      Value: 1
    11. Create: Number of UPS outlets #16573861
      Value: 1
    12. Create: Efficiency #16573862
      Value: 88 %
    13. Create: THD #16573863
      Value: 3 %
    14. Create: Min. input voltage #16573864
      Value: 176 V
    15. Create: Max. input voltage #16573865
      Value: 300 V
    16. Create: Min. input frequency #16573866
      Value: 46 Hz
    17. Create: Max. input frequency #16573867
      Value: 64 Hz
    18. Create: Input power factor #16573868
      Value: 0.98
    19. Create: Output voltage stability Battery mode #16573869
      Value: 2 %
    20. Create: Crest factor #16573870
      Value: 3
    21. Create: Fuse type #16573871
      Value: Auto
    22. Create: Protection functions #16573872
      Value: Short circuit protection, high voltage surge protection, overload protection
    23. Create: Interfaces #16573873
      Value: RS-232, USB, slot
    24. Create: Charging time #16573874
      Value: 4 h
    25. Create: Information display #16573875
      Value: LCD screen
    26. Create: Peculiarities #16573876
      Value: Battery swappable, rackmountable, audible alarm, SNMP support, additional battery connection, noise filtering, cold start
    27. Create: Noise level #16573877
      Value: 58 dB
    28. Create: Depth #16573878
      Value: 580 mm
    29. Create: Weight #16573879
      Value: 20 kg
    30. Create: Height in units #16573880
      Value: 3 U
    31. Create: Additional Information #16573881
      Value: Battery pack dimensions 438x133x580 mm, weight 63 kg.
    32. Create: Image #13089468
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id5378041330426171918/orig
    33. Create: Image #13089469
      URL: https://avatars.mds.yandex.net/get-mpic/1081556/img_id1772104121985473853/orig
    34. Create: Preview image #13089470
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id5378041330426171918/orig
  2. Donny Darko 23 April 2023 18:26:39
    Name: Double conversion UPS Tuncmatik Newtech Pro 10kVA LCD Rack-Mount; Catalog: Uninterruptible power supplies