Change history for item: Double conversion UPS P-Com PC-MEM H 1KVA

  1. Donny Darko 24 August 2023 13:02:03
    1. Create: Width #431811
      Value: 144
    2. Create: Height #431812
      Value: 215
    3. Create: Description #16570601
      Value: Total output power: 1000 VA, active output power: 700 W, type of output power connectors: CEE 7 euro socket, IEC 320 C13 computer, total number of output power connectors: 3, interfaces: RS-232
    4. Create: Brand #16570602
      Value: P-Com
    5. Create: Output power apparent #16570603
      Value: 1000 VA
    6. Create: Output power active #16570604
      Value: 700 W
    7. Create: Output waveform #16570605
      Value: Sinusoid
    8. Create: Input voltage #16570606
      Value: 1-phase
    9. Create: Output voltage #16570607
      Value: 1-phase
    10. Create: Number of output power connectors total #16570608
      Value: 3
    11. Create: Type of output power connectors #16570609
      Value: CEE 7 euro socket, IEC 320 C13 computer
    12. Create: Efficiency #16570610
      Value: 87 %
    13. Create: THD #16570611
      Value: 5 %
    14. Create: Min. input voltage #16570612
      Value: 115 V
    15. Create: Max. input voltage #16570613
      Value: 295 V
    16. Create: Min. input frequency #16570614
      Value: 45 Hz
    17. Create: Max. input frequency #16570615
      Value: 65 Hz
    18. Create: Input power factor #16570616
      Value: 0.98
    19. Create: Output voltage stability Battery mode #16570617
      Value: 2 %
    20. Create: Crest factor #16570618
      Value: 3
    21. Create: Fuse type #16570619
      Value: Melting
    22. Create: Protection functions #16570620
      Value: Short circuit protection, high voltage surge protection, overload protection, telephone line protection
    23. Create: Interfaces #16570621
      Value: RS-232
    24. Create: Charging time #16570622
      Value: 8 h
    25. Create: Information display #16570623
      Value: LCD screen
    26. Create: Peculiarities #16570624
      Value: Automatic By-pass, battery replacement option, audible alarm, additional battery connection, manual By-pass, interference filtering, cold start
    27. Create: Depth #16570625
      Value: 361 mm
    28. Create: Weight #16570626
      Value: 5.2 kg
    29. Create: Additional Information #16570627
      Value: Without batteries
    30. Create: Image #13089102
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id7077006562708304815/orig
    31. Create: Image #13089103
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id5339861584071991493/orig
    32. Create: Image #13089104
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id98745788917837797/orig
    33. Create: Preview image #13089105
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id7077006562708304815/orig
  2. Donny Darko 23 April 2023 18:26:22
    Name: Double conversion UPS P-Com PC-MEM H 1KVA; Catalog: Uninterruptible power supplies