Change history for item: Double conversion UPS P-Com PC-MEM RTS 2 kVA

  1. Donny Darko 24 August 2023 13:01:54
    1. Create: Width #431803
      Value: 131
    2. Create: Height #431804
      Value: 440
    3. Create: Description #16570305
      Value: Total output power: 2000 VA, active output power: 1600 W, type of output power connectors: IEC 320 C13 computer, total number of output power connectors: 6, height in units: 3 U, interfaces: RS-232
    4. Create: Brand #16570306
      Value: P-Com
    5. Create: Output power apparent #16570307
      Value: 2000 VA
    6. Create: Output power active #16570308
      Value: 1600 W
    7. Create: Output waveform #16570309
      Value: Sinusoid
    8. Create: Input voltage #16570310
      Value: 1-phase
    9. Create: Output voltage #16570311
      Value: 1-phase
    10. Create: Number of output power connectors total #16570312
      Value: 6
    11. Create: Type of output power connectors #16570313
      Value: IEC 320 C13 computer
    12. Create: Efficiency #16570314
      Value: 87 %
    13. Create: THD #16570315
      Value: 7 %
    14. Create: Min. input voltage #16570316
      Value: 115 V
    15. Create: Max. input voltage #16570317
      Value: 295 V
    16. Create: Min. input frequency #16570318
      Value: 45 Hz
    17. Create: Max. input frequency #16570319
      Value: 65 Hz
    18. Create: Input power factor #16570320
      Value: 0.98
    19. Create: Output voltage stability Battery mode #16570321
      Value: 2 %
    20. Create: Crest factor #16570322
      Value: 3
    21. Create: Protection functions #16570323
      Value: Short circuit protection, high voltage surge protection, overload protection
    22. Create: Interfaces #16570324
      Value: RS-232
    23. Create: Charging time #16570325
      Value: 8 h
    24. Create: Information display #16570326
      Value: LCD screen
    25. Create: Peculiarities #16570327
      Value: Automatic By-pass, Battery swappable, Rack-mountable, Audible alarm, Additional battery connection, Manual By-pass, Noise filtering, Cold start
    26. Create: Depth #16570328
      Value: 520 mm
    27. Create: Weight #16570329
      Value: 22 kg
    28. Create: Height in units #16570330
      Value: 3 U
    29. Create: Image #13089070
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id4681871401491446225/orig
    30. Create: Image #13089071
      URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id8605728299050990828/orig
    31. Create: Preview image #13089072
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id4681871401491446225/orig
  2. Donny Darko 23 April 2023 18:26:21
    Name: Double conversion UPS P-Com PC-MEM RTS 2 kVA; Catalog: Uninterruptible power supplies