Change history for item: ProLogiX Optimum-500 UPS

  1. Donny Darko 24 August 2023 12:39:01
    1. Create: Width #430679
      Value: 115
    2. Create: Height #430680
      Value: 160
    3. Create: Description #16535574
      Value: Total output power: 500 VA, active output power: 300 W, type of output power connectors: CEE 7 euro socket, Number of UPS output power connectors: 1, total number of power output connectors: 1, interfaces
    4. Create: Brand #16535575
      Value: ProLogiX
    5. Create: Output power apparent #16535576
      Value: 500 VA
    6. Create: Output power active #16535577
      Value: 300 W
    7. Create: Output waveform #16535578
      Value: Sinusoid
    8. Create: Switchover time to battery #16535579
      Value: 8 ms
    9. Create: Input voltage #16535580
      Value: 1-phase
    10. Create: Output voltage #16535581
      Value: 1-phase
    11. Create: Number of output power connectors total #16535582
      Value: 1
    12. Create: Number of UPS outlets #16535583
      Value: 1
    13. Create: Type of output power connectors #16535584
      Value: CEE 7 euro socket
    14. Create: Efficiency #16535585
      Value: 75 %
    15. Create: Min. input voltage #16535586
      Value: 150 V
    16. Create: Max. input voltage #16535587
      Value: 275 V
    17. Create: Min. input frequency #16535588
      Value: 45 Hz
    18. Create: Max. input frequency #16535589
      Value: 65 Hz
    19. Create: Output voltage stability Battery mode #16535590
      Value: 5 %
    20. Create: Protection functions #16535591
      Value: Short circuit protection, high voltage surge protection, overload protection
    21. Create: Interfaces #16535592
      Value: RS-232
    22. Create: Information display #16535593
      Value: LCD screen
    23. Create: Peculiarities #16535594
      Value: Possibility of replacing batteries, sound alarm, connection of additional batteries, noise filtering, cold start
    24. Create: Noise level #16535595
      Value: 56 dB
    25. Create: Depth #16535596
      Value: 290 mm
    26. Create: Weight #16535597
      Value: 5.1 kg
    27. Create: Image #13084309
      URL: https://avatars.mds.yandex.net/get-mpic/1565610/img_id5755774919083665592/orig
    28. Create: Image #13084310
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id5952653359831478440/orig
    29. Create: Preview image #13084311
      URL: https://avatars.mds.yandex.net/get-mpic/1565610/img_id5755774919083665592/orig
  2. Donny Darko 23 April 2023 18:23:24
    Name: ProLogiX Optimum-500 UPS; Catalog: Uninterruptible power supplies