Change history for item: Double conversion UPS EAST EA960RM LCDH

  1. Donny Darko 24 August 2023 12:24:09
    1. Create: Width #430026
      Value: 482
    2. Create: Height #430027
      Value: 360
    3. Create: Description #16513032
      Value: Total output power: 6000 VA, active output power: 4200 W, total output power connectors: 1, full load operation time: 6 min, interfaces: RS-232
    4. Create: Brand #16513033
      Value: EAST
    5. Create: Output power apparent #16513034
      Value: 6000 VA
    6. Create: Output power active #16513035
      Value: 4200 W
    7. Create: Operating time at full load #16513036
      Value: 6 min
    8. Create: Operating time at half load #16513037
      Value: 15 minutes
    9. Create: Output waveform #16513038
      Value: Sinusoid
    10. Create: Input voltage #16513039
      Value: 1-phase
    11. Create: Output voltage #16513040
      Value: 1-phase
    12. Create: Number of output power connectors total #16513041
      Value: 1
    13. Create: Efficiency #16513042
      Value: 85 %
    14. Create: THD #16513043
      Value: 5 %
    15. Create: Min. input voltage #16513044
      Value: 176 V
    16. Create: Max. input voltage #16513045
      Value: 276 V
    17. Create: Min. input frequency #16513046
      Value: 45 Hz
    18. Create: Max. input frequency #16513047
      Value: 54 Hz
    19. Create: Input power factor #16513048
      Value: 0.95
    20. Create: Output voltage stability Battery mode #16513049
      Value: 5 %
    21. Create: Crest factor #16513050
      Value: 3
    22. Create: Fuse type #16513051
      Value: Auto
    23. Create: Protection functions #16513052
      Value: Short circuit protection, high voltage surge protection, overload protection
    24. Create: Interfaces #16513053
      Value: RS-232
    25. Create: Charging time #16513054
      Value: 5 h
    26. Create: Information display #16513055
      Value: LCD screen
    27. Create: Peculiarities #16513056
      Value: Auto By-pass, Battery swappable, Rack mountable, Audible alarm, SNMP support, Optional battery connection, Manual By-pass, Noise filtering, Cold start
    28. Create: Noise level #16513057
      Value: 45 dB
    29. Create: Depth #16513058
      Value: 570 mm
    30. Create: Weight #16513059
      Value: 29.5 kg
    31. Create: Additional Information #16513060
      Value: No built-in batteries
    32. Create: Image #13081054
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id2453914457328018377/orig
    33. Create: Preview image #13081055
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id2453914457328018377/orig
  2. Donny Darko 23 April 2023 18:21:27
    Name: Double conversion UPS EAST EA960RM LCDH; Catalog: Uninterruptible power supplies