Change history for item: Double conversion UPS EAST EA960 LCDH

  1. Donny Darko 24 August 2023 12:23:44
    1. Create: Width #430004
      Value: 240
    2. Create: Height #430005
      Value: 545
    3. Create: Description #16512241
      Value: Output power apparent: 6000 VA, output power active: 4200 W, type of output power connectors: IEC 320 C13 computer, number of output power connectors total: 1, full load time: 6 min, interface
    4. Create: Brand #16512242
      Value: EAST
    5. Create: Output power apparent #16512243
      Value: 6000 VA
    6. Create: Output power active #16512244
      Value: 4200 W
    7. Create: Operating time at full load #16512245
      Value: 6 min
    8. Create: Operating time at half load #16512246
      Value: 15 minutes
    9. Create: Output waveform #16512247
      Value: Sinusoid
    10. Create: Input voltage #16512248
      Value: 1-phase
    11. Create: Output voltage #16512249
      Value: 1-phase
    12. Create: Number of output power connectors total #16512250
      Value: 1
    13. Create: Type of output power connectors #16512251
      Value: IEC 320 C13 computer
    14. Create: THD #16512252
      Value: 5 %
    15. Create: Min. input voltage #16512253
      Value: 176 V
    16. Create: Max. input voltage #16512254
      Value: 290 V
    17. Create: Min. input frequency #16512255
      Value: 45 Hz
    18. Create: Max. input frequency #16512256
      Value: 54 Hz
    19. Create: Output voltage stability Battery mode #16512257
      Value: 5 %
    20. Create: Crest factor #16512258
      Value: 3
    21. Create: Fuse type #16512259
      Value: Auto
    22. Create: Protection functions #16512260
      Value: Short circuit protection, high voltage surge protection, overload protection
    23. Create: Interfaces #16512261
      Value: RS-232
    24. Create: Charging time #16512262
      Value: 5 h
    25. Create: Information display #16512263
      Value: LCD screen
    26. Create: Peculiarities #16512264
      Value: Automatic By-pass, battery replacement, audible alarm, SNMP support, additional battery connection, noise filtering, cold start
    27. Create: Noise level #16512265
      Value: 50 dB
    28. Create: Depth #16512266
      Value: 445 mm
    29. Create: Weight #16512267
      Value: 37 kg
    30. Create: Additional Information #16512268
      Value: No built-in batteries
    31. Create: Image #13080981
      URL: https://avatars.mds.yandex.net/get-mpic/1620389/img_id6004457979988167923/orig
    32. Create: Preview image #13080982
      URL: https://avatars.mds.yandex.net/get-mpic/1620389/img_id6004457979988167923/orig
  2. Donny Darko 23 April 2023 18:21:23
    Name: Double conversion UPS EAST EA960 LCDH; Catalog: Uninterruptible power supplies