Change history for item: Double conversion UPS CROWN CMUOA-350-1K IEC

  1. Donny Darko 24 August 2023 12:22:07
    1. Create: Width #429922
      Value: 145
    2. Create: Height #429923
      Value: 220
    3. Create: Description #16509560
      Value: Output power apparent: 1000 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 4, total number of power output connectors: 4, time
    4. Create: Brand #16509561
      Value: CROWN MICRO
    5. Create: Output power apparent #16509562
      Value: 1000 VA
    6. Create: Output power active #16509563
      Value: 900 W
    7. Create: Operating time at full load #16509564
      Value: 5.2 min
    8. Create: Operating time at half load #16509565
      Value: 14 min
    9. Create: Output waveform #16509566
      Value: Sinusoid
    10. Create: Input voltage #16509567
      Value: 1-phase
    11. Create: Output voltage #16509568
      Value: 1-phase
    12. Create: Number of output power connectors total #16509569
      Value: 4
    13. Create: Number of UPS outlets #16509570
      Value: 4
    14. Create: Type of output power connectors #16509571
      Value: IEC 320 C13 computer
    15. Create: THD #16509572
      Value: 4 %
    16. Create: Min. input voltage #16509573
      Value: 110 V
    17. Create: Max. input voltage #16509574
      Value: 300 V
    18. Create: Min. input frequency #16509575
      Value: 40 Hz
    19. Create: Max. input frequency #16509576
      Value: 70 Hz
    20. Create: Input power factor #16509577
      Value: 0.9
    21. Create: Output voltage stability Battery mode #16509578
      Value: 1 %
    22. Create: Crest factor #16509579
      Value: 3
    23. Create: Fuse type #16509580
      Value: Auto
    24. Create: Protection functions #16509581
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    25. Create: Interfaces #16509582
      Value: Ethernet, RS-232, USB, slot, dry contacts
    26. Create: Charging time #16509583
      Value: 4 h
    27. Create: Information display #16509584
      Value: LCD screen
    28. Create: Peculiarities #16509585
      Value: Audible alarm, SNMP support, connection of additional batteries, noise filtering, cold start
    29. Create: Noise level #16509586
      Value: 50 dB
    30. Create: Depth #16509587
      Value: 397 mm
    31. Create: Weight #16509588
      Value: 12.5 kg
    32. Create: Image #13080633
      URL: https://avatars.mds.yandex.net/get-mpic/4322217/img_id2000048993134733957.jpeg/orig
    33. Create: Image #13080634
      URL: https://avatars.mds.yandex.net/get-mpic/3986638/img_id5418319611595889402.jpeg/orig
    34. Create: Image #13080635
      URL: https://avatars.mds.yandex.net/get-mpic/4386141/img_id867576124821186962.jpeg/orig
    35. Create: Image #13080636
      URL: https://avatars.mds.yandex.net/get-mpic/5236119/img_id486689437211411521.jpeg/orig
    36. Create: Image #13080637
      URL: https://avatars.mds.yandex.net/get-mpic/1331400/img_id1154143421522218566.jpeg/orig
    37. Create: Image #13080638
      URL: https://avatars.mds.yandex.net/get-mpic/5277894/img_id3209436838115289427.jpeg/orig
    38. Create: Image #13080639
      URL: https://avatars.mds.yandex.net/get-mpic/1924580/img_id1012333919285944041.jpeg/orig
    39. Create: Preview image #13080640
      URL: https://avatars.mds.yandex.net/get-mpic/4322217/img_id2000048993134733957.jpeg/orig
  2. Donny Darko 23 April 2023 18:21:09
    Name: Double conversion UPS CROWN CMUOA-350-1K IEC; Catalog: Uninterruptible power supplies