Change history for item: Double conversion UPS FSP Group KN-1103-TS

  1. Donny Darko 24 August 2023 12:15:34
    1. Create: Width #429639
      Value: 190
    2. Create: Height #429640
      Value: 318
    3. Create: Description #16501812
      Value: Output power apparent: 3000 VA, output power active: 2400 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 6, number of output power connectors total: 6, inter
    4. Create: Brand #16501813
      Value: FSP Group
    5. Create: Output power apparent #16501814
      Value: 3000 VA
    6. Create: Output power active #16501815
      Value: 2400 W
    7. Create: Output waveform #16501816
      Value: Sinusoid
    8. Create: Input voltage #16501817
      Value: 1-phase
    9. Create: Output voltage #16501818
      Value: 1-phase
    10. Create: Number of output power connectors total #16501819
      Value: 6
    11. Create: Number of UPS outlets #16501820
      Value: 6
    12. Create: Type of output power connectors #16501821
      Value: IEC 320 C13 computer
    13. Create: Efficiency #16501822
      Value: 88 %
    14. Create: THD #16501823
      Value: 6 %
    15. Create: Min. input voltage #16501824
      Value: 110 V
    16. Create: Max. input voltage #16501825
      Value: 300 V
    17. Create: Min. input frequency #16501826
      Value: 40 Hz
    18. Create: Max. input frequency #16501827
      Value: 70 Hz
    19. Create: Input power factor #16501828
      Value: 0.99
    20. Create: Output voltage stability Battery mode #16501829
      Value: 1 %
    21. Create: Crest factor #16501830
      Value: 3
    22. Create: Fuse type #16501831
      Value: Auto
    23. Create: Protection functions #16501832
      Value: Short circuit protection, overload protection
    24. Create: Interfaces #16501833
      Value: RS-232, USB, slot
    25. Create: Charging time #16501834
      Value: 4 h
    26. Create: Information display #16501835
      Value: LCD screen
    27. Create: Peculiarities #16501836
      Value: Audible alarm, SNMP support
    28. Create: Depth #16501837
      Value: 419 mm
    29. Create: Image #13079251
      URL: https://avatars.mds.yandex.net/get-mpic/4408567/img_id3203389030708851491.jpeg/orig
    30. Create: Image #13079252
      URL: https://avatars.mds.yandex.net/get-mpic/1526692/img_id475004961439674972.jpeg/orig
    31. Create: Preview image #13079253
      URL: https://avatars.mds.yandex.net/get-mpic/4408567/img_id3203389030708851491.jpeg/orig
  2. Donny Darko 23 April 2023 18:20:19
    Name: Double conversion UPS FSP Group KN-1103-TS; Catalog: Uninterruptible power supplies