Change history for item: Double conversion UPS N-Power Pro-Vision Black M1000 P RT

  1. Donny Darko 24 August 2023 11:55:11
    1. Create: Width #428644
      Value: 440
    2. Create: Height #428645
      Value: 88
    3. Create: Description #16472755
      Value: Total output power: 1000 VA, active output power: 900 W, type of output power connectors: IEC 320 C13 computer, total number of output power connectors: 3, height in units: 2 U, interfaces: RS-232, USB, slot
    4. Create: Brand #16472756
      Value: N-Power
    5. Create: Output power apparent #16472757
      Value: 1000 VA
    6. Create: Output power active #16472758
      Value: 900 W
    7. Create: Output waveform #16472759
      Value: Sinusoid
    8. Create: Input voltage #16472760
      Value: 1-phase
    9. Create: Output voltage #16472761
      Value: 1-phase
    10. Create: Number of output power connectors total #16472762
      Value: 3
    11. Create: Type of output power connectors #16472763
      Value: IEC 320 C13 computer
    12. Create: Efficiency #16472764
      Value: 91 %
    13. Create: THD #16472765
      Value: 6 %
    14. Create: Min. input voltage #16472766
      Value: 110 V
    15. Create: Max. input voltage #16472767
      Value: 300 V
    16. Create: Min. input frequency #16472768
      Value: 40 Hz
    17. Create: Max. input frequency #16472769
      Value: 70 Hz
    18. Create: Input power factor #16472770
      Value: 0.99
    19. Create: Min. output frequency #16472771
      Value: 50 Hz
    20. Create: Max. output frequency #16472772
      Value: 60 Hz
    21. Create: Crest factor #16472773
      Value: 3
    22. Create: Fuse type #16472774
      Value: Auto
    23. Create: Protection functions #16472775
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection
    24. Create: Interfaces #16472776
      Value: RS-232, USB, slot
    25. Create: Information display #16472777
      Value: LCD screen
    26. Create: Peculiarities #16472778
      Value: Auto By-pass, Rackmountable, Audible Alarm, Noise Filtering, Cold Start
    27. Create: Noise level #16472779
      Value: 50 dB
    28. Create: Depth #16472780
      Value: 468 mm
    29. Create: Weight #16472781
      Value: 12.26 kg
    30. Create: Height in units #16472782
      Value: 2 U
    31. Create: Image #13072055
      URL: https://avatars.mds.yandex.net/get-mpic/3986581/img_id8103320511207016678.jpeg/orig
    32. Create: Image #13072056
      URL: https://avatars.mds.yandex.net/get-mpic/4055817/img_id5842232209654569298.jpeg/orig
    33. Create: Image #13072057
      URL: https://avatars.mds.yandex.net/get-mpic/4303516/img_id1800414461160386032.jpeg/orig
    34. Create: Preview image #13072058
      URL: https://avatars.mds.yandex.net/get-mpic/3986581/img_id8103320511207016678.jpeg/orig
  2. Donny Darko 23 April 2023 18:17:39
    Name: Double conversion UPS N-Power Pro-Vision Black M1000 P RT; Catalog: Uninterruptible power supplies