    3. Create: Description #16443394
      Value: Output power apparent: 2200 VA, output power active: 1980 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 8, number of output power connectors total: 8, height
    4. Create: Brand #16443395
      Value: MGE
    5. Create: Output power apparent #16443396
      Value: 2200 VA
    6. Create: Output power active #16443397
      Value: 1980 W
    7. Create: Output waveform #16443398
      Value: Sinusoid
    8. Create: Input voltage #16443399
      Value: 1-phase
    9. Create: Output voltage #16443400
      Value: 1-phase
    10. Create: Number of output power connectors total #16443401
      Value: 8
    11. Create: Number of UPS outlets #16443402
      Value: 8
    12. Create: Type of output power connectors #16443403
      Value: IEC 320 C13 computer
    13. Create: Min. input voltage #16443404
      Value: 100 V
    14. Create: Max. input voltage #16443405
      Value: 284 V
    15. Create: Min. input frequency #16443406
      Value: 40 Hz
    16. Create: Max. input frequency #16443407
      Value: 70 Hz
    17. Create: Input power factor #16443408
      Value: 0.9
    18. Create: Interfaces #16443409
      Value: RS-232, USB, slot
    19. Create: Information display #16443410
      Value: LCD screen
    20. Create: Peculiarities #16443411
      Value: Auto By-pass, Battery swappable, Rack mountable, Battery hot-swappable, Audible alarm, SNMP support, Optional battery connection, Manual By-pass, Cold start
    21. Create: Noise level #16443412
      Value: 45 dB
    22. Create: Depth #16443413
      Value: 490 mm
    23. Create: Weight #16443414
      Value: 30 kg
    24. Create: Height in units #16443415
      Value: 3 U
    25. Create: Additional Information #16443416
      Value: Vertical and horizontal installation possible
    26. Create: Image #13068824
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id5648668879316357172/orig
    27. Create: Image #13068825
      URL: https://avatars.mds.yandex.net/get-mpic/1525999/img_id3697026896961785099/orig
    28. Create: Preview image #13068826
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id5648668879316357172/orig
  2. Donny Darko 23 April 2023 18:15:13
    Name: Double conversion UPS MGE Pulsar M 2200 RT3U HotSwap; Catalog: Uninterruptible power supplies