Change history for item: Interactive UPS MGE Pulsar Evolution 3000VA Rack 2U

  1. Donny Darko 24 August 2023 11:36:05
    1. Create: Width #427676
      Value: 438
    2. Create: Height #427677
      Value: 88
    3. Create: Description #16442942
      Value: Output power apparent: 2880 VA, output power active: 2000 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 6, number of output power connectors total: 6, height
    4. Create: Brand #16442943
      Value: MGE
    5. Create: Output power apparent #16442944
      Value: 2880 VA
    6. Create: Output power active #16442945
      Value: 2000 W
    7. Create: Output waveform #16442946
      Value: Sinusoid
    8. Create: Input voltage #16442947
      Value: 1-phase
    9. Create: Output voltage #16442948
      Value: 1-phase
    10. Create: Number of output power connectors total #16442949
      Value: 6
    11. Create: Number of UPS outlets #16442950
      Value: 6
    12. Create: Type of output power connectors #16442951
      Value: IEC 320 C13 computer
    13. Create: Min. input voltage #16442952
      Value: 160 V
    14. Create: Max. input voltage #16442953
      Value: 294 V
    15. Create: Min. input frequency #16442954
      Value: 47 Hz
    16. Create: Max. input frequency #16442955
      Value: 70 Hz
    17. Create: Output voltage stability Battery mode #16442956
      Value: 6 %
    18. Create: Min. output frequency #16442957
      Value: 49 Hz
    19. Create: Max. output frequency #16442958
      Value: 51 Hz
    20. Create: Fuse type #16442959
      Value: Auto
    21. Create: Protection functions #16442960
      Value: LAN protection, short circuit protection, overload protection
    22. Create: Interfaces #16442961
      Value: RS-232, USB, slot
    23. Create: Information display #16442962
      Value: LED indicators
    24. Create: Peculiarities #16442963
      Value: Battery swappable, rackmountable, galvanic isolation, battery hot-swappable, audible alarm, additional battery connection, noise filtering, cold start
    25. Create: Noise level #16442964
      Value: 40 dB
    26. Create: Depth #16442965
      Value: 640 mm
    27. Create: Weight #16442966
      Value: 36.5 kg
    28. Create: Height in units #16442967
      Value: 2 U
    29. Create: Additional Information #16442968
      Value: 2 of the 6 power outlets can be programmed to turn off or start in sequence the loads connected to them
    30. Create: Image #13068664
      URL: https://avatars.mds.yandex.net/get-mpic/200316/img_id8248924660534312813/orig
    31. Create: Preview image #13068665
      URL: https://avatars.mds.yandex.net/get-mpic/200316/img_id8248924660534312813/orig
  2. Donny Darko 23 April 2023 18:15:11
    Name: Interactive UPS MGE Pulsar Evolution 3000VA Rack 2U; Catalog: Uninterruptible power supplies