Change history for item: Double conversion UPS CyberPower OL10KERT3UPM

  1. Donny Darko 24 August 2023 11:34:24
    1. Create: Width #427592
      Value: 433
    2. Create: Height #427593
      Value: 132
    3. Create: Description #16440966
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16440967
      Value: CyberPower
    5. Create: Output power apparent #16440968
      Value: 10000 VA
    6. Create: Output power active #16440969
      Value: 9000 W
    7. Create: Operating time at full load #16440970
      Value: 4 min
    8. Create: Operating time at half load #16440971
      Value: 11 min
    9. Create: Output waveform #16440972
      Value: Sinusoid
    10. Create: Max. absorbed pulse energy #16440973
      Value: 2430 J
    11. Create: Input voltage #16440974
      Value: 1-phase
    12. Create: Output voltage #16440975
      Value: 1-phase
    13. Create: Number of output power connectors total #16440976
      Value: 9
    14. Create: Number of UPS outlets #16440977
      Value: 9
    15. Create: Type of output power connectors #16440978
      Value: IEC 320 C13 computer
    16. Create: Efficiency #16440979
      Value: 95 %
    17. Create: THD #16440980
      Value: 5 %
    18. Create: Min. input voltage #16440981
      Value: 180 V
    19. Create: Max. input voltage #16440982
      Value: 280 V
    20. Create: Min. input frequency #16440983
      Value: 40 Hz
    21. Create: Max. input frequency #16440984
      Value: 70 Hz
    22. Create: Input power factor #16440985
      Value: 0.99
    23. Create: Output voltage stability Battery mode #16440986
      Value: 2 %
    24. Create: Min. output frequency #16440987
      Value: 50 Hz
    25. Create: Max. output frequency #16440988
      Value: 60 Hz
    26. Create: Crest factor #16440989
      Value: 3
    27. Create: Fuse type #16440990
      Value: Auto
    28. Create: Protection functions #16440991
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    29. Create: Interfaces #16440992
      Value: RS-232, USB, slot, dry contacts
    30. Create: Charging time #16440993
      Value: 5 h
    31. Create: Information display #16440994
      Value: LCD screen
    32. Create: Peculiarities #16440995
      Value: Auto By-pass, Battery Swappable, Rack Mountable, Battery Hot Swap, Audible Alarm, SNMP Support, Optional Batteries, Manual By-pass, Noise Filtering, Cold
    33. Create: Noise level #16440996
      Value: 65 dB
    34. Create: Depth #16440997
      Value: 660 mm
    35. Create: Weight #16440998
      Value: 24 kg
    36. Create: Height in units #16440999
      Value: 6 U
    37. Create: Additional Information #16441000
      Value: Output connectors - terminal block 1 pc, sockets IEC C19 x 4 pcs and IEC C13 x 4 pcs; additional LED indication; EPO port
    38. Create: Image #13067578
      URL: https://avatars.mds.yandex.net/get-mpic/1599966/img_id7210936379370341330.jpeg/orig
    39. Create: Image #13067579
      URL: https://avatars.mds.yandex.net/get-mpic/4012150/img_id664112881483415372.jpeg/orig
    40. Create: Image #13067580
      URL: https://avatars.mds.yandex.net/get-mpic/1345185/img_id2678773298070126476.jpeg/orig
    41. Create: Image #13067581
      URL: https://avatars.mds.yandex.net/get-mpic/1345185/img_id5816101585030623563.jpeg/orig
    42. Create: Image #13067582
      URL: https://avatars.mds.yandex.net/get-mpic/5303146/img_id6447292272423538384.jpeg/orig
    43. Create: Preview image #13067583
      URL: https://avatars.mds.yandex.net/get-mpic/1599966/img_id7210936379370341330.jpeg/orig
  2. Donny Darko 23 April 2023 18:14:58
    Name: Double conversion UPS CyberPower OL10KERT3UPM; Catalog: Uninterruptible power supplies