Change history for item: Double conversion UPS CyberPower OLS6000EC

  1. Donny Darko 24 August 2023 11:30:53
    1. Create: Width #427440
      Value: 196
    2. Create: Height #427441
      Value: 702
    3. Create: Description #16435235
      Value: Output power apparent: 6000 VA, output power active: 4800 W, operating time at full load: 5 min, interfaces: RS-232, USB, slot
    4. Create: Brand #16435236
      Value: CyberPower
    5. Create: Output power apparent #16435237
      Value: 6000 VA
    6. Create: Output power active #16435238
      Value: 4800 W
    7. Create: Operating time at full load #16435239
      Value: 5 minutes
    8. Create: Operating time at half load #16435240
      Value: 13 min
    9. Create: Output waveform #16435241
      Value: Sinusoid
    10. Create: Max. absorbed pulse energy #16435242
      Value: 445 J
    11. Create: Input voltage #16435243
      Value: 1-phase
    12. Create: Output voltage #16435244
      Value: 1-phase
    13. Create: Efficiency #16435245
      Value: 96 %
    14. Create: THD #16435246
      Value: 5 %
    15. Create: Min. input voltage #16435247
      Value: 110 V
    16. Create: Max. input voltage #16435248
      Value: 276 V
    17. Create: Input power factor #16435249
      Value: 0.99
    18. Create: Output voltage stability Battery mode #16435250
      Value: 10 %
    19. Create: Min. output frequency #16435251
      Value: 50 Hz
    20. Create: Max. output frequency #16435252
      Value: 60 Hz
    21. Create: Crest factor #16435253
      Value: 3
    22. Create: Fuse type #16435254
      Value: Auto
    23. Create: Protection functions #16435255
      Value: Short circuit protection, overload protection
    24. Create: Interfaces #16435256
      Value: RS-232, USB, slot
    25. Create: Charging time #16435257
      Value: 7 h
    26. Create: Information display #16435258
      Value: LED indicators
    27. Create: Peculiarities #16435259
      Value: Automatic By-pass, audible alarm, SNMP support, cold start
    28. Create: Noise level #16435260
      Value: 60 dB
    29. Create: Depth #16435261
      Value: 412 mm
    30. Create: Weight #16435262
      Value: 5.4 kg
    31. Create: Additional Information #16435263
      Value: Input and output connectors in the form of a terminal block
    32. Create: Image #13065681
      URL: https://avatars.mds.yandex.net/get-mpic/4322217/img_id4853651713099306744.jpeg/orig
    33. Create: Image #13065682
      URL: https://avatars.mds.yandex.net/get-mpic/4401552/img_id2282669105271253045.jpeg/orig
    34. Create: Image #13065683
      URL: https://avatars.mds.yandex.net/get-mpic/4113189/img_id7505958448655975114.jpeg/orig
    35. Create: Image #13065684
      URL: https://avatars.mds.yandex.net/get-mpic/1581127/img_id7255319943891578013.jpeg/orig
    36. Create: Image #13065685
      URL: https://avatars.mds.yandex.net/get-mpic/4948493/img_id4892496151708157826.jpeg/orig
    37. Create: Image #13065686
      URL: https://avatars.mds.yandex.net/get-mpic/5253116/img_id8310378479739075593.jpeg/orig
    38. Create: Image #13065687
      URL: https://avatars.mds.yandex.net/get-mpic/4113189/img_id2784890642931837033.jpeg/orig
    39. Create: Image #13065688
      URL: https://avatars.mds.yandex.net/get-mpic/5094021/img_id5218436103665542781.jpeg/orig
    40. Create: Image #13065689
      URL: https://avatars.mds.yandex.net/get-mpic/5277279/img_id6108655458376463367.jpeg/orig
    41. Create: Preview image #13065690
      URL: https://avatars.mds.yandex.net/get-mpic/4322217/img_id4853651713099306744.jpeg/orig
  2. Donny Darko 23 April 2023 18:14:32
    Name: Double conversion UPS CyberPower OLS6000EC; Catalog: Uninterruptible power supplies