Change history for item: Double conversion UPS CyberPower OLS3000EC

  1. Donny Darko 24 August 2023 11:30:51
    1. Create: Width #427438
      Value: 196
    2. Create: Height #427439
      Value: 343
    3. Create: Description #16435154
      Value: Output power apparent: 3000 VA, output power active: 2400 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 4, total number of power output connectors: 4, time
    4. Create: Brand #16435155
      Value: CyberPower
    5. Create: Output power apparent #16435156
      Value: 3000 VA
    6. Create: Output power active #16435157
      Value: 2400 W
    7. Create: Operating time at full load #16435158
      Value: 3.5 min
    8. Create: Operating time at half load #16435159
      Value: 10 min
    9. Create: Output waveform #16435160
      Value: Sinusoid
    10. Create: Max. absorbed pulse energy #16435161
      Value: 220 J
    11. Create: Input voltage #16435162
      Value: 1-phase
    12. Create: Output voltage #16435163
      Value: 1-phase
    13. Create: Number of output power connectors total #16435164
      Value: 4
    14. Create: Number of UPS outlets #16435165
      Value: 4
    15. Create: Type of output power connectors #16435166
      Value: IEC 320 C13 computer
    16. Create: Efficiency #16435167
      Value: 95 %
    17. Create: THD #16435168
      Value: 5 %
    18. Create: Min. input voltage #16435169
      Value: 160 V
    19. Create: Max. input voltage #16435170
      Value: 300 V
    20. Create: Input power factor #16435171
      Value: 0.98
    21. Create: Output voltage stability Battery mode #16435172
      Value: 15 %
    22. Create: Crest factor #16435173
      Value: 3
    23. Create: Fuse type #16435174
      Value: Auto
    24. Create: Protection functions #16435175
      Value: Short circuit protection, high voltage surge protection, overload protection
    25. Create: Interfaces #16435176
      Value: RS-232 slot
    26. Create: Charging time #16435177
      Value: 4 h
    27. Create: Information display #16435178
      Value: LCD screen
    28. Create: Peculiarities #16435179
      Value: Auto By-pass, Audible Alarm, SNMP Support, Manual By-pass, Cold Start
    29. Create: Noise level #16435180
      Value: 45 dB
    30. Create: Depth #16435181
      Value: 416 mm
    31. Create: Weight #16435182
      Value: 28.01 kg
    32. Create: Additional Information #16435183
      Value: Additional terminal block
    33. Create: Image #13065665
      URL: https://avatars.mds.yandex.net/get-mpic/1417902/img_id2035622650213342943.jpeg/orig
    34. Create: Image #13065666
      URL: https://avatars.mds.yandex.net/get-mpic/4012481/img_id989802462214349265.jpeg/orig
    35. Create: Image #13065667
      URL: https://avatars.mds.yandex.net/get-mpic/4303516/img_id6904650464535599595.jpeg/orig
    36. Create: Image #13065668
      URL: https://avatars.mds.yandex.net/get-mpic/5217690/img_id381718431126783742.jpeg/orig
    37. Create: Image #13065669
      URL: https://avatars.mds.yandex.net/get-mpic/5254518/img_id6703976740530732311.jpeg/orig
    38. Create: Image #13065670
      URL: https://avatars.mds.yandex.net/get-mpic/1705137/img_id1233778781408714070.jpeg/orig
    39. Create: Image #13065671
      URL: https://avatars.mds.yandex.net/get-mpic/5217690/img_id8336488894717444309.jpeg/orig
    40. Create: Image #13065672
      URL: https://avatars.mds.yandex.net/get-mpic/5345452/img_id421564811817891778.png/orig
    41. Create: Preview image #13065673
      URL: https://avatars.mds.yandex.net/get-mpic/1417902/img_id2035622650213342943.jpeg/orig
  2. Donny Darko 23 April 2023 18:14:31
    Name: Double conversion UPS CyberPower OLS3000EC; Catalog: Uninterruptible power supplies