Change history for item: Double conversion UPS CyberPower OL6000E

  1. Donny Darko 24 August 2023 11:30:18
    1. Create: Width #427412
      Value: 265
    2. Create: Height #427413
      Value: 600
    3. Create: Description #16434251
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16434252
      Value: CyberPower
    5. Create: Output power apparent #16434253
      Value: 6000 VA
    6. Create: Output power active #16434254
      Value: 5400 W
    7. Create: Operating time at full load #16434255
      Value: 5 minutes
    8. Create: Operating time at half load #16434256
      Value: 15 minutes
    9. Create: Output waveform #16434257
      Value: Sinusoid
    10. Create: Max. absorbed pulse energy #16434258
      Value: 2430 J
    11. Create: Input voltage #16434259
      Value: 1-phase
    12. Create: Output voltage #16434260
      Value: 1-phase
    13. Create: Number of output power connectors total #16434261
      Value: 10
    14. Create: Number of UPS outlets #16434262
      Value: 10
    15. Create: THD #16434263
      Value: 5 %
    16. Create: Min. input voltage #16434264
      Value: 180 V
    17. Create: Max. input voltage #16434265
      Value: 280 V
    18. Create: Input power factor #16434266
      Value: 0.99
    19. Create: Output voltage stability Battery mode #16434267
      Value: 2 %
    20. Create: Crest factor #16434268
      Value: 3
    21. Create: Fuse type #16434269
      Value: Auto
    22. Create: Protection functions #16434270
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    23. Create: Interfaces #16434271
      Value: RS-232, slot, dry contacts
    24. Create: Charging time #16434272
      Value: 4 h
    25. Create: Information display #16434273
      Value: LCD screen
    26. Create: Peculiarities #16434274
      Value: Auto By-pass, Battery Swappable, Battery Hot Swap, Audible Alarm, SNMP Support, Additional Batteries, Manual By-pass, Cold Start
    27. Create: Depth #16434275
      Value: 660 mm
    28. Create: Weight #16434276
      Value: 9.5 kg
    29. Create: Additional Information #16434277
      Value: Emergency Power Off EPO port; additional input and output connectors in the form of a terminal block; output connectors IEC C13 x 8 pcs and IEC C19 x 2
    30. Create: Image #13065430
      URL: https://avatars.mds.yandex.net/get-mpic/1374520/img_id5152647936809831924.jpeg/orig
    31. Create: Image #13065431
      URL: https://avatars.mds.yandex.net/get-mpic/1345185/img_id2653702550164977366.jpeg/orig
    32. Create: Image #13065432
      URL: https://avatars.mds.yandex.net/get-mpic/1364191/img_id4046873297421204102.jpeg/orig
    33. Create: Preview image #13065433
      URL: https://avatars.mds.yandex.net/get-mpic/1374520/img_id5152647936809831924.jpeg/orig
  2. Donny Darko 23 April 2023 18:14:28
    Name: Double conversion UPS CyberPower OL6000E; Catalog: Uninterruptible power supplies