    3. Create: Description #16409944
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16409945
      Value: Powercom
    5. Create: Output power apparent #16409946
      Value: 10000 VA
    6. Create: Output power active #16409947
      Value: 9000 W
    7. Create: Operating time at full load #16409948
      Value: 5 minutes
    8. Create: Operating time at half load #16409949
      Value: 10 min
    9. Create: Output waveform #16409950
      Value: Sinusoid
    10. Create: Max. absorbed pulse energy #16409951
      Value: 3245 J
    11. Create: Input voltage #16409952
      Value: 1-phase
    12. Create: Output voltage #16409953
      Value: 1-phase
    13. Create: Number of output power connectors total #16409954
      Value: 8
    14. Create: Type of output power connectors #16409955
      Value: IEC 320 C13 computer
    15. Create: Min. input voltage #16409956
      Value: 220 V
    16. Create: Max. input voltage #16409957
      Value: 240 V
    17. Create: Min. input frequency #16409958
      Value: 50 Hz
    18. Create: Max. input frequency #16409959
      Value: 60 Hz
    19. Create: Output voltage stability Battery mode #16409960
      Value: 2 %
    20. Create: Min. output frequency #16409961
      Value: 50 Hz
    21. Create: Max. output frequency #16409962
      Value: 60 Hz
    22. Create: Fuse type #16409963
      Value: Auto
    23. Create: Protection functions #16409964
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    24. Create: Interfaces #16409965
      Value: RS-232, USB, dry contacts
    25. Create: Charging time #16409966
      Value: 4 h
    26. Create: Information display #16409967
      Value: LCD screen
    27. Create: Peculiarities #16409968
      Value: Battery replacement, audible alarm, SNMP support, connection of additional batteries, interference filtering, cold start
    28. Create: Noise level #16409969
      Value: 60 dB
    29. Create: Depth #16409970
      Value: 642 mm
    30. Create: Weight #16409971
      Value: 95.5 kg
    31. Create: Additional Information #16409972
      Value: Output connectors: terminal block and sockets 4 pcs - IEC320 C13 + 4 pcs x C19
    32. Create: Image #13059762
      URL: https://avatars.mds.yandex.net/get-mpic/4519143/img_id4241463022436277144.jpeg/orig
    33. Create: Image #13059763
      URL: https://avatars.mds.yandex.net/get-mpic/4113189/img_id5184088060269059134.jpeg/orig
    34. Create: Image #13059764
      URL: https://avatars.mds.yandex.net/get-mpic/4420180/img_id3087475842324134186.jpeg/orig
    35. Create: Preview image #13059765
      URL: https://avatars.mds.yandex.net/get-mpic/4519143/img_id4241463022436277144.jpeg/orig
  2. Donny Darko 23 April 2023 18:12:37
    Name: Double Conversion UPS Powercom VANGUARD VGS-10K; Catalog: Uninterruptible power supplies