Change history for item: Double conversion UPS Powercom Vanguard VGD-5000 RM 3U

  1. Donny Darko 24 August 2023 11:14:31
    1. Create: Width #426675
      Value: 428
    2. Create: Height #426676
      Value: 130
    3. Create: Description #16409035
      Value: Output power apparent: 5000 VA, output power active: 3500 W, Number of UPS outputs: 1, total outputs: 1, full load time: 2 min, HU: 3 U
    4. Create: Brand #16409036
      Value: Powercom
    5. Create: Output power apparent #16409037
      Value: 5000 VA
    6. Create: Output power active #16409038
      Value: 3500 W
    7. Create: Operating time at full load #16409039
      Value: 2 minutes
    8. Create: Operating time at half load #16409040
      Value: 6 min
    9. Create: Output waveform #16409041
      Value: Sinusoid
    10. Create: Input voltage #16409042
      Value: 1-phase
    11. Create: Output voltage #16409043
      Value: 1-phase
    12. Create: Number of output power connectors total #16409044
      Value: 1
    13. Create: Number of UPS outlets #16409045
      Value: 1
    14. Create: Efficiency #16409046
      Value: 95 %
    15. Create: THD #16409047
      Value: 5 %
    16. Create: Min. input voltage #16409048
      Value: 160 V
    17. Create: Max. input voltage #16409049
      Value: 276 V
    18. Create: Min. input frequency #16409050
      Value: 45 Hz
    19. Create: Max. input frequency #16409051
      Value: 65 Hz
    20. Create: Output voltage stability Battery mode #16409052
      Value: 2 %
    21. Create: Fuse type #16409053
      Value: Auto
    22. Create: Protection functions #16409054
      Value: Short circuit protection, high voltage surge protection, overload protection
    23. Create: Interfaces #16409055
      Value: RS-232, USB, dry contacts
    24. Create: Charging time #16409056
      Value: 4 h
    25. Create: Information display #16409057
      Value: LCD screen
    26. Create: Peculiarities #16409058
      Value: Automatic by-pass, battery swappable, rackmountable, audible alarm, additional battery connection, noise filtering, cold start
    27. Create: Noise level #16409059
      Value: 55 dB
    28. Create: Depth #16409060
      Value: 657 mm
    29. Create: Weight #16409061
      Value: 40 kg
    30. Create: Height in units #16409062
      Value: 3 U
    31. Create: Additional Information #16409063
      Value: Terminal block
    32. Create: Image #13059594
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id6717113641059333768/orig
    33. Create: Preview image #13059595
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id6717113641059333768/orig
  2. Donny Darko 23 April 2023 18:12:33
    Name: Double conversion UPS Powercom Vanguard VGD-5000 RM 3U; Catalog: Uninterruptible power supplies