Change history for item: Double Conversion UPS Powercom Vanguard VGD-10000

  1. Donny Darko 24 August 2023 11:12:22
    1. Create: Width #426567
      Value: 257
    2. Create: Height #426568
      Value: 715
    3. Create: Description #16406130
      Value: Output power apparent: 10000 VA, output power active: 7000 W, operating time at full load: 5 min, interfaces: RS-232, USB, slot, dry contacts
    4. Create: Brand #16406131
      Value: Powercom
    5. Create: Output power apparent #16406132
      Value: 10000 VA
    6. Create: Output power active #16406133
      Value: 7000 W
    7. Create: Operating time at full load #16406134
      Value: 5 minutes
    8. Create: Operating time at half load #16406135
      Value: 13 min
    9. Create: Output waveform #16406136
      Value: Sinusoid
    10. Create: Max. absorbed pulse energy #16406137
      Value: 480 J
    11. Create: Input voltage #16406138
      Value: 1-phase
    12. Create: Output voltage #16406139
      Value: 1-phase
    13. Create: Efficiency #16406140
      Value: 97 %
    14. Create: THD #16406141
      Value: 3 %
    15. Create: Min. input voltage #16406142
      Value: 180 V
    16. Create: Max. input voltage #16406143
      Value: 276 V
    17. Create: Min. input frequency #16406144
      Value: 45 Hz
    18. Create: Max. input frequency #16406145
      Value: 65 Hz
    19. Create: Output voltage stability Battery mode #16406146
      Value: 2 %
    20. Create: Min. output frequency #16406147
      Value: 50 Hz
    21. Create: Max. output frequency #16406148
      Value: 60 Hz
    22. Create: Crest factor #16406149
      Value: 3
    23. Create: Fuse type #16406150
      Value: Auto
    24. Create: Protection functions #16406151
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    25. Create: Interfaces #16406152
      Value: RS-232, USB, slot, dry contacts
    26. Create: Charging time #16406153
      Value: 4 h
    27. Create: Information display #16406154
      Value: LCD screen
    28. Create: Peculiarities #16406155
      Value: Automatic by-pass, battery changeable, audible alarm, manual by-pass, noise filtering, cold start
    29. Create: Noise level #16406156
      Value: 55 dB
    30. Create: Depth #16406157
      Value: 690 mm
    31. Create: Weight #16406158
      Value: 112 kg
    32. Create: Additional Information #16406159
      Value: Output connectors: terminal block
    33. Create: Image #13058906
      URL: https://avatars.mds.yandex.net/get-mpic/200316/img_id340440693244682575/orig
    34. Create: Preview image #13058907
      URL: https://avatars.mds.yandex.net/get-mpic/200316/img_id340440693244682575/orig
  2. Donny Darko 23 April 2023 18:12:18
    Name: Double Conversion UPS Powercom Vanguard VGD-10000; Catalog: Uninterruptible power supplies