Change history for item: Double conversion UPS Powerman Online Plus 1000

  1. Donny Darko 24 August 2023 11:02:16
    1. Create: Width #426079
      Value: 144
    2. Create: Height #426080
      Value: 293
    3. Create: Description #16391414
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16391415
      Value: Powerman
    5. Create: Without battery #16391416
      Value: There is
    6. Create: Output power apparent #16391417
      Value: 1000 VA
    7. Create: Output power active #16391418
      Value: 900 W
    8. Create: Output waveform #16391419
      Value: Sinusoid
    9. Create: Input voltage #16391420
      Value: 1-phase
    10. Create: Output voltage #16391421
      Value: 1-phase
    11. Create: Number of output power connectors total #16391422
      Value: 2
    12. Create: Number of UPS outlets #16391423
      Value: 2
    13. Create: Type of output power connectors #16391424
      Value: CEE 7 euro socket
    14. Create: Efficiency #16391425
      Value: 88 %
    15. Create: THD #16391426
      Value: 3 %
    16. Create: Min. input voltage #16391427
      Value: 115 V
    17. Create: Max. input voltage #16391428
      Value: 295 V
    18. Create: Min. input frequency #16391429
      Value: 40 Hz
    19. Create: Max. input frequency #16391430
      Value: 70 Hz
    20. Create: Input power factor #16391431
      Value: 0.98
    21. Create: Output voltage stability Battery mode #16391432
      Value: 1 %
    22. Create: Fuse type #16391433
      Value: Auto
    23. Create: Protection functions #16391434
      Value: Short circuit protection, high voltage surge protection, overload protection
    24. Create: Interfaces #16391435
      Value: RS-232, USB, slot, dry contacts
    25. Create: Information display #16391436
      Value: LCD screen
    26. Create: Peculiarities #16391437
      Value: Automatic By-pass, audible alarm, SNMP support, connection of additional batteries, through neutral, cold start
    27. Create: Noise level #16391438
      Value: 40 dB
    28. Create: Depth #16391439
      Value: 209 mm
    29. Create: Weight #16391440
      Value: 42 kg
    30. Create: Image #13053466
      URL: https://avatars.mds.yandex.net/get-mpic/1925870/img_id113736862659455009.jpeg/orig
    31. Create: Image #13053467
      URL: https://avatars.mds.yandex.net/get-mpic/1961245/img_id8554105926726713721.jpeg/orig
    32. Create: Image #13053468
      URL: https://avatars.mds.yandex.net/get-mpic/6256254/img_id1609309608597139531.jpeg/orig
    33. Create: Image #13053469
      URL: https://avatars.mds.yandex.net/get-mpic/5254754/img_id3815444432945903124.jpeg/orig
    34. Create: Image #13053470
      URL: https://avatars.mds.yandex.net/get-mpic/5234525/img_id8548994852078827940.jpeg/orig
    35. Create: Image #13053471
      URL: https://avatars.mds.yandex.net/get-mpic/4590616/img_id7829686385727159948.jpeg/orig
    36. Create: Image #13053472
      URL: https://avatars.mds.yandex.net/get-mpic/5236177/img_id5161152780921325402.jpeg/orig
    37. Create: Image #13053473
      URL: https://avatars.mds.yandex.net/get-mpic/3689399/img_id7301983142571260426.jpeg/orig
    38. Create: Preview image #13053474
      URL: https://avatars.mds.yandex.net/get-mpic/1925870/img_id113736862659455009.jpeg/orig
  2. Donny Darko 23 April 2023 18:10:49
    Name: Double conversion UPS Powerman Online Plus 1000; Catalog: Uninterruptible power supplies