Change history for item: Interactive UPS Mustek PowerMust 3027S NetGuard

  1. Donny Darko 24 August 2023 10:32:12
    1. Create: Width #424789
      Value: 438
    2. Create: Height #424790
      Value: 86
    3. Create: Description #16347806
      Value: Output power apparent: 3000 VA, output power active: 2700 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 9, total number of power output connectors: 9, time
    4. Create: Brand #16347807
      Value: Mustek
    5. Create: Output power apparent #16347808
      Value: 3000 VA
    6. Create: Output power active #16347809
      Value: 2700 W
    7. Create: Operating time at full load #16347810
      Value: 3 min
    8. Create: Operating time at half load #16347811
      Value: 10 min
    9. Create: Output waveform #16347812
      Value: Sinusoid
    10. Create: Switchover time to battery #16347813
      Value: 6 ms
    11. Create: Input voltage #16347814
      Value: 1-phase
    12. Create: Output voltage #16347815
      Value: 1-phase
    13. Create: Number of output power connectors total #16347816
      Value: 9
    14. Create: Number of UPS outlets #16347817
      Value: 9
    15. Create: Type of output power connectors #16347818
      Value: IEC 320 C13 computer
    16. Create: THD #16347819
      Value: 6 %
    17. Create: Min. input voltage #16347820
      Value: 154 V
    18. Create: Max. input voltage #16347821
      Value: 288 V
    19. Create: Input power factor #16347822
      Value: 0.9
    20. Create: Output voltage stability Battery mode #16347823
      Value: 5 %
    21. Create: Protection functions #16347824
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    22. Create: Interfaces #16347825
      Value: RS-232, USB, slot
    23. Create: Charging time #16347826
      Value: 4 h
    24. Create: Information display #16347827
      Value: LCD screen
    25. Create: Peculiarities #16347828
      Value: Battery swappable, rackmountable, audible alarm, noise filtering, cold start
    26. Create: Noise level #16347829
      Value: 47 dB
    27. Create: Depth #16347830
      Value: 608 mm
    28. Create: Weight #16347831
      Value: 30.4 kg
    29. Create: Image #13042918
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id1872988335565797441/orig
    30. Create: Image #13042919
      URL: https://avatars.mds.yandex.net/get-mpic/4080967/img_id520004023918034027.jpeg/orig
    31. Create: Preview image #13042920
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id1872988335565797441/orig
  2. Donny Darko 23 April 2023 18:06:06
    Name: Interactive UPS Mustek PowerMust 3027S NetGuard; Catalog: Uninterruptible power supplies