Change history for item: Double conversion UPS General Electric NetPro 4000

  1. Donny Darko 24 August 2023 10:28:16
    1. Create: Width #424589
      Value: 220
    2. Create: Height #424590
      Value: 293
    3. Create: Description #16341590
      Value: Total output power: 4000 VA, active output power: 2400 W, type of output power connectors: IEC 320 C13 computer, total number of output power connectors: 3, interfaces: RS-232, slot
    4. Create: Brand #16341591
      Value: General Electric
    5. Create: Output power apparent #16341592
      Value: 4000 VA
    6. Create: Output power active #16341593
      Value: 2400 W
    7. Create: Output waveform #16341594
      Value: Sinusoid
    8. Create: Switchover time to battery #16341595
      Value: 1 ms
    9. Create: Input voltage #16341596
      Value: 1-phase
    10. Create: Output voltage #16341597
      Value: 1-phase
    11. Create: Number of output power connectors total #16341598
      Value: 3
    12. Create: Type of output power connectors #16341599
      Value: IEC 320 C13 computer
    13. Create: Min. input voltage #16341600
      Value: 187 V
    14. Create: Max. input voltage #16341601
      Value: 264 V
    15. Create: Min. input frequency #16341602
      Value: 45 Hz
    16. Create: Max. input frequency #16341603
      Value: 65 Hz
    17. Create: Output voltage stability Battery mode #16341604
      Value: 1 %
    18. Create: Fuse type #16341605
      Value: Melting
    19. Create: Protection functions #16341606
      Value: Short circuit protection, high voltage surge protection, overload protection
    20. Create: Interfaces #16341607
      Value: RS-232 slot
    21. Create: Charging time #16341608
      Value: 1.5 h
    22. Create: Information display #16341609
      Value: LCD screen
    23. Create: Peculiarities #16341610
      Value: Automatic by-pass, audible alarm, manual by-pass, interference filtering, cold start
    24. Create: Depth #16341611
      Value: 557 mm
    25. Create: Weight #16341612
      Value: 42 kg
    26. Create: Additional Information #16341613
      Value: Batteries are in a separate case with the same dimensions as the main unit and weighing 21.3 kg;
    27. Create: Image #13042130
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id8777898250030045269/orig
    28. Create: Preview image #13042131
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id8777898250030045269/orig
  2. Donny Darko 23 April 2023 18:05:35
    Name: Double conversion UPS General Electric NetPro 4000; Catalog: Uninterruptible power supplies